INSTALLATION INSTRUCTIONS

Congratulations on purchasing the
finest water feature for installation in your project!

Take a few moments to familiarize yourself with this unit and to inventory the parts. Now is a good time to take the brass jet, brass cover plate, and the four mounting screws and store them in a safe place until all lines have been pressure checked and flushed. Install these items at pool start-up.

The AquaStream Decorative Jet is designed to be mounted either vertically or horizontally. When mounted vertically it is usually mounted in the pool wall slightly above the water level; when mounted horizontally it is usually mounted on a pool deck. However, the applications are limited only by the installers own imagination - wall cap mounting, in reflection pools, goldfish ponds, and planters are just a few that come to mind.

POOL WALL INSTALLATION:

NOTE: When it is desired that the jets provide equal distance water streams, risers should be of equal length. If the risers cannot be of equal length each AquaStream should be valved separately.

NOTE:  Prevent dirt, organic matter, rock or gravel from entering the plumbing lines. Clean pipes of debris and either tape the ends or cap them during construction.

INSTALLING IN A DECK:

CAUTION:  Protect the surface of the AquaStream housing, cover while deck is under construction.

NOTE:  When it is desired that the jets provide equal distance water streams, risers should be of equal length. If the risers cannot be of equal length each AquaStream should be valved separately.

NOTE:  Prevent dirt, organic matter, rock or gravel from entering the plumbing lines. Clean pipes of debris and either tape the ends or cap them during construction.

INSTALLING IN A CONCRETE BEAM:

PLUMBING THE AQUASTREAM:

Table 1.
Distance of stream* 6' 12' 19' 25'
Feet of  head 4' 8' 12' 16'
GPM 2 3 3.7 4.4
*Stream distance @45 degree angle of projection

See Plumbing Layout